Details about ARBURG 77TON INJECTION MOLDING MACHINE, MODEL 305S-210-700, 77 TON. Voltage: 230/460, 3Ph / 60Hz. Machine is under power in good working condition. Machine has 39,000 hours approx. Operation and Maintenance Manual Included. SPEC’S SUBJECT TO FINAL INSPECTION! Item is offered “AS IS WHERE IS”. LOCAL PICK UP. Cases 8th edition, 99 chevy silverado repair manual, 111 questions on islam samir khalil samir on islam and the west, arburg polytronica manual, best pmp study guide, food microbiology practical manual, build a better booty, yanmar excavator service manual, ce 6511 soil mechanics lab experiment in all reading in answer, intellectual property rights.
- Arburg Polytronica Manuals
- Arburg Polytronica Manual Download
- Arburg Polytronica Manual
- Arburg Polytronica Manual Free
We offer: Vertical set-up device for unit Arburg 270 40 mm tie bars 45mm Manufacturer: Arburg Weight: approx. 15 kg Condition: used, as seen, ready for use, see photos, Further ersat parts, accessories such as tilting aid Arburg 270, 420 C and extension for Arburg 320, conveyors, dosers etc. Device for vertically setting up injection unit Arburg 270M - Device e.g. Vertik.set up injection. 1972 was the year in ARBURG’s history in which new control system standards were set. A fully electronic controller for injec-tion moulding machines was introduced at ARBURG with the fi rst PolytronICA on an ALLROUNDER. The world’s fi rst stand-ard microprocessor controller was used by ARBURG in the ALLROUNDER H from 1975 onwards. We support you satisfying the end-user's needs in fast changing white-goods market. Clamping force: kN. Arburg injection molding machine manual pdf. Maya 2014 – professional 3d modeling and animation tool. Kg Ejector force max. Then we will carry out all the necessary revision work, so that the machine will be in a good technical condition. 2 Electric 1.
Thermonic SN 46.531 |
Arburg injection moulding machine allrounder K, H and H-D have dedicated PID temperature controllers
for cylinder heating, nozzle heating at the plasticizing unit.
These temperature controllers i.e. Thermonics have a D-PID characteristics therefore, no temperature peak on start-up and no steady deviation. It has 3+1 configuration of Thermonics, i.e. 3 Thermonics for cylinder heating zones and one Thermonic for nozzle heating; ensures precise temperature profile on cylinder and nozzle.
Thermonic has an in- built under temperature protection circuit so that screw rotation is inhibited if
A. Input signal sampling and amplification.
C. Overload protection circuit & SSR protection circuit.
There are many models of temperature controllers which were used on Arburg machines.
Thermonic SN 36.346, SN 31.980,SN 34.600, SN 39.507, SN 31.980 : switching the supply to heater band via triac.
Thermonic SN 40.787, SN 40.788, SN 46.530, SN 46.531, SN 52.022 : switching the supply to heater band via SSR.
Thermonic SN 53.013, SN 71.356, SN 71.357 : switching the supply to heater band via SSR.
Sanjadha Enterprises expertise in repair and calibration of Thermonics of all models.We have adequate stocks of spare parts and components required for repair of Thermonics.
We undertake complete overhaul, repair and reconditioning of Thermonics.
Thermonic SN 39.600 |
Synventive 8 zone Hi-Q hot runner temperature controller |
It is a 2 zone temperature controller with versatile operation required for hot runner temperature controller. It was available in single zone ( HIQBOX1S), 4 zones (HIQBOX4) ,8 zones ( HIQBOX8) , 12 zones (HIQBOX12) and 24 zones (HIQBOX24) cabinets.
Synventive 2 zone Hi-Q hot runner temperature controller-side view |
Arburg Polytronica Manuals
Arburg Polytronica Manual Download
Synventive 2 zone Hi-Q hot runner temperature controller |
1. ON-OFF problem: It switches off during operation and switches on after some time.
2. Actual Temperature indications : 0 ° C / 0 ° C
3. Actual Temperature indications : 500 ° C / 0 ° C, 0 ° C / 500 ° C
4. Actual Temperature indications : tc ¯ ° C / tc ¯ ° C , tc ¯ ° C / 0 ¯ ° C
5. Actual Temperature indications : 0 ° C / SHO ° C, SHO ° C / 0 ° C, SHO ° C / SHO ° C
6. No display
7. No display -complete dead unit.
Various reasons for failure of Hi-Q cards are as given below:
a. Unhealthy 3 phase + neutral+ earth connections.
b. Improper connections to thermocouples and heaters.
Arburg Polytronica Manual
c. Malfunctioning of cooling fans installed on the cabinet.
d. Incoming mains voltage with severe power surges.
e. Components failure due to ageing,dust,moisture etc.
Now we are confident that in 99.0% cases we can revive Hi-Q card completely irrespective of the the nature of problems. 1.0 % cases is when the card is subjected to severe power surges ( short duration voltage current spikes in the electrical environment) for longer period/periods. We have upgraded our testing + repair facilities and also the required stock of spares needed to achieve this.